A full-size ASIC miner is an industrial machine. It draws as much power as a clothes dryer, runs louder than a vacuum cleaner, and turns all of that electricity into heat, every hour of every day. Plenty of people mine at home anyway. This guide is about doing it without tripping breakers, annoying the neighbors or cooking the machine.
Power: the circuit comes first
Most full-size miners can't plug into a regular wall outlet. Bitmain's Antminer S21 (3,500 W) and L9 (3,360 W), for example, take 220 to 277 volts. In a US home that means a 240-volt circuit, the kind used for a dryer or an electric range.
A miner is also a continuous load: it runs for hours at full power. The electrical code says continuous loads should use no more than 80% of a circuit's rating. Here's what that leaves you:
| Circuit | Safe all-day load | Usual copper wire | Enough for |
|---|---|---|---|
| 120 V, 15 A | 1,440 W | 14 AWG | Small home miners |
| 120 V, 20 A | 1,920 W | 12 AWG | One mid-size home miner |
| 240 V, 20 A | 3,840 W | 12 AWG | One full-size miner, if its rated maximum current allows |
| 240 V, 30 A | 5,760 W | 10 AWG | One full-size miner with room to spare |
A 3,500 W miner at 240 V draws about 14.6 amps, which fits within a 20-amp circuit's 16-amp all-day limit. But Bitmain rates the S21 for up to 20 amps of input current, and an electrician sizing the circuit to the rated maximum may call for 30 amps and heavier wire. Let them decide.
Use a licensed electrician for any new circuit. Permit rules vary by city and county, and your homeowner's insurance may care. Bitmain also says to ground the miner properly and leave headroom in the power supply. Don't run a miner on an extension cord or an adapter.
The planner asks how much power you can supply and only suggests machines that fit.
Noise: louder than a vacuum, all night
Manufacturers rate full-size air-cooled miners at about 75 to 76 decibels: Bitmain lists 76 dBA for the S21 Pro and 75 dBA for the L9 at full fan speed. For comparison, normal conversation is about 60 dBA and a vacuum cleaner about 70 dBA. Every 10 dB sounds roughly twice as loud, so a miner sounds well over twice as loud as a conversation, and it never stops.
That's below the 85 dBA level the CDC's workplace safety agency treats as hazardous over an eight-hour day, so it's unlikely to hurt your hearing at a distance. But in a living space it's hard to ignore, and Bitmain itself warns that its machines can get very loud at home.
What helps:
- A garage, basement, shed or outbuilding with a door between the miner and where people sleep.
- Distance and walls; noise drops quickly with both.
- Ducting or a sound-dampening enclosure built for miners, as long as it still moves enough air. Never seal a miner in a box.
- Checking local noise rules if the machine is near a neighbor's window.
Heat: two or three space heaters
Almost every watt a miner draws becomes heat. One watt is 3.412 BTU per hour, so a 3,500 W miner puts out about 11,900 BTU per hour. A typical space heater tops out at 1,500 W (about 5,100 BTU per hour), so one miner is like running two or three space heaters on high, nonstop.
Bitmain's guidance for its machines is to run them somewhere between about 5 and 35 °C (41 to 95 °F) with humidity below 65%, with unobstructed air flow, never in an enclosed space, and with regular dust cleaning. Its spec sheets allow a wider range, but the recommended range is what keeps a machine running for years.
- Pull cool air in from one side and push hot air out of the building, not back into the same room.
- In winter, the heat can warm a garage or workshop, which offsets some of the power cost.
- In summer, a closed room can overheat in hours. Plan for exhaust before July, not during it.
- Avoid damp spaces; condensation and dust are what kill hashboards.
Miners built for homes
If a 240-volt circuit and a roaring fan aren't realistic, there are smaller machines designed for homes. They earn far less, and at typical home power prices they rarely pay back, but they're a quiet way to learn how mining works.
| Machine | Hashrate | Power | Noise | Plugs into |
|---|---|---|---|---|
| Canaan Avalon Q | 90 TH/s | up to 1,674 W | 45 to 65 dB | 110 to 240 V; at full power on 120 V it needs a 20 A circuit |
| Canaan Avalon Mini 3 | 37.5 TH/s | up to 800 W | 33 to 55 dB | 110 to 240 V outlet |
| Canaan Avalon Nano 3S | 6 TH/s | up to 140 W | 33 to 40 dB | Its own power adapter |
| Bitaxe Gamma | about 1.2 TH/s | under 30 W | Not published | 5 V power supply |
Figures are from the manufacturers' pages. Each machine's StackingHash page shows what it earns at your power price and the current lowest price.
Before you plug anything in
- Check the miner's input voltage and maximum current on the manufacturer's spec sheet.
- Have a licensed electrician install a dedicated circuit sized for it, with a permit if your area needs one.
- Pick a space where the noise won't reach bedrooms or a neighbor's window.
- Plan where the hot air goes, and how you'll keep the space below about 35 °C in summer.
- Keep it dry and away from dust, and plan to blow out the fans and heat sinks regularly.
- Work out the electricity cost at your real rate, using the calculator or a miner's page, before you buy.
If the answers point away from home, hosting is the alternative.
Sources
- Bitmain: Antminer S21 specification
- Bitmain: Antminer S21 Pro specification
- Bitmain: Antminer L9 specifications
- Bitmain: Precautions for use
- Bitmain: Environmental requirements for Antminers
- Bitmain: Check if Antminers can be used at home
- IAEI Magazine: 100% vs 80%, choosing the right overcurrent protection
- Electrical Safety Foundation International: DIY electrical safety
- American Speech-Language-Hearing Association: Loud noise dangers
- CDC NIOSH: About noise and hearing loss
- U.S. EIA: Energy conversion calculators
- Office of Congressional Workplace Rights: Space heaters
- Canaan: Avalon Mini 3
- Canaan: Avalon Q
- Canaan: Avalon Nano 3S
- Bitaxe Gamma (open-source hardware project)